Home > Ecc Error > Ecc Error 3ware

Ecc Error 3ware

Contents

If a read command to a sector on a disk drive results in an error, it reverts to the redundant copy in order to satisfy the host's request. The Battery Backup Unit is not ready and is unable to backup the 3ware RAID controller. With twelve terabytes you have to pull it six times! If the primary copy is valid, the backup DCB will be rewritten to rectify the errors.

Action: None required. 0056 Battery charging completed Event Type: Information Cause: The Battery Backup Unit has completed a battery charge cycle. 0057 Battery charging fault Event Type: Error Cause: The Battery If the unit is non-redundant a unit file system check is recommended. This isn't something most people should worry about with their 3Ware RAIDs! See your enclosure documentation or contact your enclosure manufacturer for more information. 8030 Enclosure power normal Event Type: Information Cause: Applies only to the 9690SA controller. http://serverfault.com/questions/332935/what-does-3wares-tw-cli-mean-by-a-degraded-disk-vs-ecc-error

3ware Ecc Error Rebuild

See your enclosure documentation or contact your enclosure manufacturer for more details. When this event happens, the Battery Backup Unit becomes not ready and is unable to backup the 3ware RAID controller. See Also Enabling or Disabling Auto Verify for a Unit Scheduling Background Tasks LSI Corporation Copyright LSI 2004-2009 To contact Support, go to http://www.lsi.com/channel/ContactUs 3DM® 2 Online Help Configuring Units > Action: Check hardware connections and reseat the drive or drives.

According to our logs, ZFS has not detected any bad sectors on this drive. Share this post Link to post Share on other sites honold 0 Member Member 0 6204 posts Posted June 13, 2003 · Report post that failure rate is very abnormal If the controller is still under warranty, contact 3ware Technical Support for a replacement controller. 025h Cache flush failed; some data lost To improve performance, this 3ware RAID controller features caching Hard Drive Ecc Error It is recommended to use an uninterruptible power supply (UPS) to protect against power failures. 8040 Enclosure voltage normal Event Type: Information Cause: Applies only to the 9690SA controller.

Action: You should replace the 3ware RAID controller. Ecc Error 3ware 9650 Action: The drive is now available for use. Internal operations such as Background Media Scan post this AEN whenever drive ECC errors are detected. http://blog.coffeebeans.at/archives/40 Action: None required. 8045 Enclosure current over Event Type: Error Cause: Applies only to the 9690SA controller.

The fact that a sector repair AEN has been sent to the user is an indication of the presence of grown defects on a particular drive. Tw_cli Ignoreecc Action: The Battery backup Unit is presently still able to backup the 3ware RAID controller, but you should replace the battery pack if the temperature warning persists and is not due Action: If this drive was the only one to lose power, check the cable connections. When this occurs the Battery Backup Unit becomes not ready and is unable to backup the 3ware RAID controller.

Ecc Error 3ware 9650

Action: None required. 8021 Enclosure temp low Event Type: Information Cause: Applies only to the 9690SA controller. http://titan.physx.u-szeged.hu/opt/3ware/3DM2/help/en/AEN_0026.html It is recommended to use an uninterruptible power supply (UPS) to protect against power failures. 8033 Enclosure power added Event Type: Information Cause: Applies only to the 9690SA controller. 3ware Ecc Error Rebuild Given Maxtor's refusal to replace 'em, it's gotta be the drives... 3ware Degraded Drive What I can't tell is if I've just suffered a double-disk failure (bummer!) or if I'm reading this wrong.

Some of the flash files with insufficient data may have been lost in the operation. Action: If due to a failing power supply, replace it as soon as possible. permalinkembedsaveparentgive gold[–]twtech 0 points1 point2 points 2 years ago(0 children)It depends on the adapter. Return all missing drives to the unit. Tw_cli Start Rebuild

This AEN is posted to the host when this health check has completed. 053h Battery capacity test is overdue The recommended time interval for running the battery capacity test is once If the voltage is below the warning threshold, this AEN will be posted to the user. So those two drives are in use in another fashion. The configuration parameters which are lost will then return to their default values. 041h Unit number assignments lost The 3ware RAID controller tries to keep the unit numbers persistent across soft

kernel: 3w-xxxx: scsi0: AEN: WARNING: Sector repair occured: port #1 Ein fehlerhafter Sektor auf der Festplatte an Port 1 wurde erkannt. Tw_cli Cheat Sheet Nach fast acht Jahren im Technischen Support wechselte er im September 2015 in das Produktmanagement um dort seine Erfahrung mit einzubringen. The BBU is unable to backup the 3ware RAID controller.

Any data that was on that unit will still be there.

This possibility applies to RAID 1, 10, 5, and 50. Allow cold equipment to warm up gradually before powering on. 8022 Enclosure temp high Event Type: Warning Cause: Applies only to the 9690SA controller. The enclosure power supply current is now back within the acceptable range. Tw_cli U From the ZFS perspective one bad sector isn't a big deal, although it might indicate that the drive is starting to go bad.

Remove the BBU control module from the 3ware RAID controller and the battery module from the remote card. 3. And my 80Gb drives arrived to me in all of the original Maxtor packaging completely unopened, negating handling as an issue... the rebound speed of silicone Term for "professional" who doesn't make their living from that kind of work Can 'it' be used to refer to a person? The enclosure power supply amperage is higher than normal.

What is the most befitting place to drop 'H'itler bomb to score decisive victory in 1945? If Maxtor says they are frying at reasonable temperatures, well that just sucks. Mai 2015 um 09:57 Uhr geändert. I read that recent recall article (and retraction) with interest.